Introduction

Rapid Brucella Ab Test kit is based on competitive immuno-chromatography technique to qualitatively detect Brucella Ab in bovine,goat,sheep and dog`s serum, plasma and whole blood. When testing, Brucella Ab in sample competition with antibody on T-line.The T line appears, means there is no Brucella Ab in the sample.

 

Contents

1

Brucella Test Device

10 pcs

2

Capillary sampling tube

10 pce

3

Dilution Buffer

1  bottle

4

Instruction for use

1  insert

 

Procedure

 Specimen: whole Blood or serum or plasma

1. Collected Blood 0.5-1mL, 3000 rev / min, centrifuged 3-5 minutes to separate the serum. Can also be 4 º C standing overnight, so that the natural precipitation of serum. Or direct test whole blood.

2. Remove the test device from the foil pouch, and place it on a flat and dry surface.

3. Take 5 μl (capillary black scale) serum or whole blood to the sample well, and then add a drop of buffer dilution.

4. Please wait 5 minutes.

5. Add two drops of buffer dilution.

6. At this time will see the wine red liquid flow through the observation window. Wait 10-15 minutes to determine the results, results will invalid after 15 minutes.

 

 Specimen: Milk

1. Collect raw milk to ensure that the sample is not spoiled and not heated.

2. Remove the test card (if refrigerated, return it to room temperature and open the package) and place it flat on the table after opening.

3. Take 20ul raw milk, add the sample wells.

4. Please wait 5 minutes.

5. Add three drops of Buffer diluent to the sample well.

6. At this time will see the wine red liquid flow through the observation window. Wait 10-15 minutes to determine the results, results will invalid after 15 minutes.

 

■ Interpretation of the test

1) Negative:Both on T Line and C line being seen wine-red color reaction.

 

 

2) Positive:no color reaction on Test Line (T Line),only on Control Line(C Line) being seen wine-red color reaction.

 

 

3) Invalid:No color reaction on C Line.

 

 

packing

10T/kit.

 

Stability and Storage

Store at 2 - 30ºC and the shelf life is 24 months.

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Recently viewed products
Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号