INTENDED USE  
The  Malaria Gold Rapid Test is a lateral flow chromatographic  
immunoassay for the simultaneous detection and differentiation of  
antibodies including IgG, IgM and IgA to Plasmodium falciparum (Pf)  
and vivax, ovale, and malariea (Pv.o.m) in whole blood. This device is  
intended to be used as a screening test and as an aid in the diagnosis of  
infection with Plasmodium. Any reactive specimen with the Malaria  
Gold Rapid Test must be confirmed with alternative testing method(s)  
and clinical findings.  
SUMMARY AND EXPLANATION OF THE TEST  
Malaria is a mosquito-borne, hemolytic, febrile illness that infects over  
200 million people and kills more than 1 million people per year. It is  
caused by four species of Plasmodium: P. falciparum, P. vivax, P.ovale,  
and P. malariae. These plasmodia all infect and destroy human  
erythrocytes, producing chills, fever, anemia, and splenomegaly. P.  
falciparum causes more sever disease than the other plasmodial species  
and accounts for most malaria deaths. P. falciparum and P. vivax are  
the most common pathogens, however, there is considerable  
geographic variation in species distribution1.  
Traditionally, malaria is diagnosed by the demonstration of the  
organisms on Giemsa stained smears of peripheral blood, and the  
different species of plasmodium are distinguished by their appearance  
in infected erythrocytes1. The technique is capable of accurate and  
reliable diagnosis, but only when performed by skilled microscopists  
using defined protocols2, which presents major obstacles for the  
remote and poor areas of the world.  
The Malaria Gold Rapid Test is developed for solving these above  
obstacles. It detects the antibodies generated in serum or plasma in  
response to the infection of plasmodium. Utilizing the Pf. specific  
antigen (HRP-II) and pan-malaria antigen (aldolase),the test enables  
simultaneous detection and differentiation of the infection of  
P.falciparum and or P. vivax, ovale,and malariae3-5, by untrained or  
minimally skilled personnel, without laboratory equipment. 
TEST PRINCIPLE  
The  Malaria Gold Rapid Test is a lateral flow chromatographic  
immunoassay. The test cassette consists of: 1) a burgundy colored  
conjugate pad containing recombinant HRP-II and aldolase conjugated  
with colloid gold (Pf conjugates and Pan-malariaconjugates) and  
rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip  
containing two test bands (T1 and T2 bands) and a control band (C  
band). The T1 band is pre-coated with recombinant HRP-II antigen for  
the detection of antibodies to Pf only, T2 band is pre-coated with  
aldolase for the detection of antibodies to Pan-malaria protozoa, and  
the C band is precoated with goat anti rabbit IgG.  
When an adequate volume of test specimen is dispensed into the  
sample well of the test cassette, the specimen migrates by capillary  
action across the cassette. Antibodies including IgG, IgM and IgA  
against HRP-II antigen, only found in P. falciparum infection, if  
present in the specimen will bind to the Pf conjugates. The  
immunocomplex is then captured on the membrane by the pre-coated  
HRP-II antigen, forming a burgundy colored T1 band, indicating a  
Pf positive test result.  
Alternatively, antibodies including IgG, IgM and IgA against aldolase,  
generated following the infection by the either form of malaria  
protozoa if present in the specimen will bind to the Panmalaria 
conjugates. The immunocomplex is then captured by the pre-coated  
aldolase antigen on the membrane, forming a burgundy colored T2  
band, indicating a plasmodium antibody positive result.  
Absence of any T bands (T1 and T2) suggests a negative result. The  
test contains an internal control (C band) which should exhibit a  
burgundy colored band of the immunocomplex of goat anti-rabbit  
IgG/rabbit IgG-gold conjugate regardless of the color development on  
any of the T bands. Otherwise, the test result is invalid and the  
specimen must be retested with another device.  
REAGENTS AND MATERIALS PROVIDED  
1.   Each kit contains 25 test devices, each sealed in a foil pouch with  
three items inside:  
a. One cassette device.  
b.   One plastic dropper.  
c. One desiccant.  
2.   Sample diluent (1 vial, 5 ml)  
3.   One package insert (instruction for use).  
MATERIALS REQUIRED BUT NOT PROVIDED  
1. Clock or Timer  
2.   Lancing device for whole blood test  
WARNINGS AND PRECAUTIONS  
For in Vitro Diagnostic Use  
1.   This package insert must be read completely before performing the  
test. Failure to follow the insert gives inaccurate test results.  
2.   Do not open the sealed pouch, unless ready to conduct the assay.  
3.   Do not use expired devices.  
4.   Bring all reagents to room temperature (15-30 °Ċ) before use.  
5. Do not use the components in any other type of test kit as a  
substitute for the components in this kit.  
6.   Do not use hemolized blood for the testing.  
7.   Wear protective clothing and disposable gloves while handling the  
kit reagents and clinical specimens. Wash hands thoroughly after  
performing the test.  
8.   Users of this test should follow the US CDC Universal Precautions  
for prevention of transmission of HIV, HBV and other  
blood-borne pathogens.  
9. Do not smoke, drink, or eat in areas where specimens or kit  
reagents are being handled.  
10. Dispose of all specimens and materials used to perform the test as  
biohazardous waste.  
11. Handle the Negative and Positive Control in the same manner as  
patient specimens.  
12. The testing results should be read within 15 minutes after a  
specimen is applied to the sample well or sample pad of the device.  
Read result after 15 minutes may give erroneous results.  
13. Do not perform the test in a room with strong air flow, ie. an  
electric fan or strong airconditioning.  
REAGENT PREPARATION AND STORAGE INSTRUCTIONS  
All reagents are ready to use as supplied. Store unused test device  
unopened at 4-30℃. The positive and negative controls should be kept  
at 2-8℃. If stored at 2-8℃, ensure that the test device is brought to  
room temperature before opening. The test device is stable through the  
expiration date printed on the sealed pouch. Do not freeze the kit or  
expose the kit over 30℃.  
SPECIMEN COLLECTION AND HANDLING  
Consider any materials of human origin as infectious and handle them  
using standard biosafety procedures.  
Plasma  
1. Collect blood specimen into a lavender, blue or green top  
collection tube (containing EDTA, citrate or heparin, respectively  
in Vacutainer®) by veinpuncture.  
2.   Separate the plasma by centrifugation.  
3.   Carefully withdraw the serum into a new pre-labeled tube.  
Serum  
1.   Collect blood specimen into a red top collection tube (containing  
no anticoagulants inVacutainer®) by veinpuncture.  
2.   Allow the blood to clot.  
3.   Separate the serum by centrifugation.  
4.   Carefully withdraw the serum into a new pre-labeled tube.  
Test specimens as soon as possible after collecting. Store specimens at  
2 to 8 °Ċif not testedimmediately.  
Store specimens at 2 to 8 °Ċup to 5 days. The specimens should be  
frozen at -20 °Ċfor longer storage.  
Avoid multiple freeze-thaw cycles. Prior to testing, bring frozen  
specimens to room temperature slowly and mix gently. Specimens  
containing visible particulate matter should be clarified by  
centrifugation before testing.  
Blood  
Drops of whole blood can be obtained by either finger tip puncture or  
veinpuncture. Do not use any hemolized blood for testing.  
Whole blood specimens should be stored in refrigeration (2°Ċ-8 °Ċ) if  
not tested immediately. The specimens must be tested within 24 hours  
of collection. 
bio-equip.cn  
  Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service. 
Efficiently structured to provide lasting and economic health care solutions with export ready goods, our main products cover the following immunodiagnostic rapid test kits: 
Rapid Tests for Human Use : 
1) Fertility: Pregnancy HCG, ovulation LH, menopause FSH 
2) Infectious diseases: Hepatitis B, HCV, HIV 
3) Drug abuse: AMP, BAR, BZO, COC, mAMP, MOP, MTD, OPI, PCP, TCA, THC 
4) Tumor markers: CEA, PSA, AFP, FOB 
5) STDs(Sexually Transmitted Diseases): Gonorrhea, syphilis, chlamydia 
6) New products: Malaria, H. Pylori, Multi-Hepatis B Panel (HBsAg, Anti-HBs, HBeAg, Anti-HBe, Anti-HBc), Blood Glucose Test, Multi-drug of Abuse Panel, Avian (Bird) Flu Rapid Test, etc. 
Rapid Tests for Veterinary : 
1) Bovine: Cow Pregnancy , Cow Ovulation, Bovine Brucella, Bovine Tuberculosis ,Food and Mouth Disease NSP Ab Test 
2) Canine: Canine Distemper, Canine Parvovirus, Canine Coronavirus 
3) Feline : Feline Leukemia Virus Ag Rapid Test ,Feline Panleucopenia Virus Ag Test,Feline Immunodeficiency Virus Ab Test 
Rapid Tests for Food Safety : 
1)For Antibiotics Residue : Nitrofurans (AOZ,AMOZ, AHD, SEM), Streptomycin , Sulfonamides , Chloramphenicol , Quinolone , Beta-Lactam&Tetracycline Combo (2 in 1), β-Lactams & Streptomycin & Chloramphenicol & Tetracyclines Combo (4 in 1), Beta-Lactam, Tetracycline test 
2) For Beta-Agonist Residue : Ractopamine, Clenbuterol ,Salbutamol
   
 
 
 |