Login    Join free Add to favorites    中文
Home >Products> Reagents >ELISA / Diagnostic Kits> Beta lactam + Tetracycline Combo Rapid Test (2 in 1)
Beta lactam + Tetracycline Combo Rapid Test (2 in 1)
Beta lactam + Tetracycline Combo Rapid Test (2 in 1)
Origin of place China
Model RF408W
Supplier Span Biotech Ltd
Price Negotiable
Hits 1028
Updated 4/25/2025
  • Product Detail
  • Company Profile

Beta lactam + Tetracycline Combo Rapid Test (2 in 1)

Package:8 strips/bottle,12 bottles/box,96 strips/box

INTENDED USE

Beta lactam + Tetracycline Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Beta lactam and Tetracycline residue in milk.

Assay Time:  5 - 10 min

Sample: milk

KIT COMPONENT

1.12×plastic canister each containing 8 microwells and 8 strips

2.96×pipettes

3.Microwell holder, 1pcs

4.Product Manual

TEST PROCEDURE

-Collect milk as testing sample.

-Take out the microwells and strips of necessary quantity from the plastic canister. Recover the milk and test kit to room temperature (20-25 °C). Do not heat the milk.

-Use pipette to transfer 200 μL of sample (a mark on the pipette) into the microwell.

-Repeatedly suck and extrude the sample until all red reagents are completely dissolved.

-Stand for 5 min and insert the “max” end of strip into the well.

-Read the result in 5 - 10 min. Result after 10 minutes is only considered as reference.

INTERPRETATION OF RESULTS

Positive: The T band does not appear.

Negative: The T band appears.

Invalid: No colored band appears in C zone.

SENSITIVITY AND SPECIFICITY

-Penicillin G 2 - 4 ppb, Ampicillin 3-4 ppb, Amoxicillin 4 - 5 ppb

-Oxacillin 6 - 8 ppb, Cloxacillin 6 – 8 ppb

-Cefacetril 100 ppb, Cefquinome 15 - 20 ppb

-Ceftiofur 50 ppb, Cefapirin 50-60 ppb.

-Tetracycline 40-60 ppb

-The results are negative when the rapid test is applied to detect 100 ppm of Chloramphenicol, Aminoglycosides, Macrolides and Sulfonamides.

STORAGE

All materials must be stored at 2 - 8°C. The test kit is stable through the expiration date (12 months) marked on the foil pouch. Do not store the test kit in direct sunlight.

PRECAUTIONS

-For best results, please strictly adhere to these instructions.

-All reagents must be at room temperature before running the assay.

-Do not remove rapid test from its pouch until immediately before use.

-The milk sample should be fresh and homogeneous liquid without caking and precipitation.

-Do not reuse the test strip.

-Do not use the test beyond its expiration date.

-Do not use water, powdered milk as negative control. Use confirmed negative fresh milk as control.

-The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers.

LIMITATION

Beta lactam + Tetracycline Rapid Test is an useful tool offering a rapid and accurate testing in field screening, exceeding with its convenience. If you want a quantitative result, it is suggested to apply other method such as ELISA / HPLC in practice.

 

 

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号