Login    Join free Add to favorites    中文
Home >Products> Reagents >ELISA / Diagnostic Kits> Reactive oxygen species ROS detection kit (green fluorescence)
Reactive oxygen species ROS detection kit (green fluorescence)
Reactive oxygen species ROS detection kit (green fluorescence)
Origin of place
Model abs580232-1000T
Supplier ANT BIO PTE.LTD.
Price 108
Hits 189
Updated 10/10/2026
  • Product Detail
  • Company Profile

Product Specification

Synonym

Reactive Oxygen Species?Assay Kit

Background

The optimal excitation wavelength is 488nm.The optimal emission wavelength is 530nm.

Storage Temp.

-20 ° C in the dark, valid for 12 months.

Applications

Adherent cells, suspended cells, fresh animal tissues

Description (Click to expand)

Dcfh-da (dichlorodihydrofluorescein-acetoacetate) itself has no fluorescence, can freely enter the cell through the living cell membrane, and is hydrolyzed by intracellular esterase to form DCFH. DCFH has no fluorescence and cannot penetrate the cell membrane, and is oxidized by intracellular reactive oxygen species to produce fluorescent DCF. According to the generation of fluorescence in living cells, cells can determine the content of active oxygen and change. It can be directly observed by flow cytometry or fluorescence microscope. It is a classical method for the detection of reactive oxygen species in tissues or living cells. Rosup positie for reactive oxygen species induced by drugs, according to the fluorescence signal intensity, the real level of reactive oxygen species can be.

ComponentNameSize
ADCFH-DA(10 mM)0.1mL
BPositive control for reactive oxygen species(Rosup 100 mM)1mL
General Notes (Click to expand)

1, the positive control Rosup is generally used at a concentration of 100μ M (recommended concentration 100-400μ M, depending on the cell type). A significant increase in reactive oxygen species levels was usually observed 30 min-4 h after stimulation. For different cells, the effect of active oxygen positive control may have bigger difference. If no increase in ROS is observed within 30 min after stimulation, the induction time can be prolonged or the concentration of ROS positive control can be appropriately increased. If the ROS level increases too rapidly, the induction time can be shortened or the concentration of the ROS positive control can be appropriately reduced.

2, experiment process, if it finds no stimulus negative control cells, fluorescence is strong, can according to the 1:2000-00 1:50 dilution DCFH - DA, make DCFH - DA final concentration of 2-5 & mu; M. The probe loading time can also be appropriately adjusted within 15-60 min depending on the situation.

3, Reactive oxygen species positive control (Rosup) is only used as a positive control of the sample, not in every sample to add reactive oxygen species positive control.

4, probe after loading, be sure to wash the residual not enter the probe of cells, otherwise it will lead to higher background.

ANT BIO PTE. LTD. – Empowering Scientific Breakthroughs At ANTBIO, we are committed to advancing life science research through high-quality, reliable reagents and comprehensive solutions. Our specialized sub-brands (Starter, Absin, UA) cover a full spectrum of research needs, from general reagents and kits to antibodies and recombinant proteins. With a focus on innovation, quality, and customer-centricity, we strive to be your trusted partner in unlocking scientific mysteries and driving medical progress. Explore our product portfolio today and elevate your research to new heights.

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2026 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号