Login    Join free Add to favorites    中文
Home >Products> Reagents >ELISA / Diagnostic Kits> Scoville Heat Units (SHU)Test Kit
Scoville Heat Units (SHU)Test Kit
Scoville Heat Units (SHU)Test Kit
Origin of place China
Model 96T
Supplier Wuhan Ecalbio Co., Ltd
Price
Hits 345
Updated 5/14/2025
  • Product Detail
  • Company Profile
Scoville Heat Units , SHU, can be calculated using Capsaicin ELISA Kit, there is the correlation of Capsaicin Content.
Pungency Degree SHU Capsaicin Content
1 0-500 0-33.3mg/kg
2 500-1000 33.3mg/kg-66.7mg/kg
3 1000-1500 66.7mg/kg-100mg/kg
4 1500-2500 100mg/kg-166.7mg/kg
5 2500-5000 166.7mg/kg-333.3mg/kg
6 5000-15000 333.3mg/kg-1000mg/kg
7 15000-30000 1000mg/kg-2000mg/kg
8 30000-50000 2000mg/kg-3333.3mg/kg
9 50000-100000 3333.3mg/kg-6666.7mg/kg
10 >100000 >6666.7mg/kg

1. Principle of Capsaicin ELISA Kit
Capsaicin ELISA Kit is a competitive ELISA for the quantitative analysis of Capsaicin in the rapeseed oil, soybean oil, peanut oil, corn oil, blended oil, etc. The coupling antigens are pre-coated on the micro-well stripes. The Capsaicin in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Cap antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with Capsaicin concentration in the sample. This value is compared to the standard curve and the content of the corresponding Capsaicin is subsequently obtained.
Enzyme immunoassay (ELISA) is widely used as a screening system, which is more simple, rapid, sensitive and cost-effective compared with HPLC or GC-MS.
 
2. Technical specifications
Sensitivity : 1ppb     Detect time: Approx. 30 min
Detection limit:
Rapeseed oil, soybean oil, peanut oil, corn oil, blended oil ............10ppb
Chili,curry powder & curry paste......................................................100ppb 
Recovery rate:
Rapeseed oil, soybean oil, peanut oil, corn oil, blended oil .......... 75±10%
Chili,curry powder & curry paste.....................................................85±10%
 
Cross-reaction rate:
Capsaicin.............................100 %
Dihydrocapsaicin..................100 %
Nonivamide..........................100 %

 

ECALBIO CO.,LTD
Email: info@ecalbio.com    Https: //www.ecalbio.com
Tel: +86-27-87745856         Mobi: +86-18963964485
Add: HZAU, Luoshi Road, Wuhan City 430075, China. 

 
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Recently viewed products
Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号