Login    Join free Add to favorites    中文
Home >Products> Reagents >ELISA / Diagnostic Kits> Foot and Mouth Disease Virus Type A Antibody ELISA Kit(FMD)
Foot and Mouth Disease Virus Type A Antibody ELISA Kit(FMD)
Foot and Mouth Disease Virus Type A Antibody ELISA Kit(FMD)
Origin of place China
Model FT0710
Supplier ibookbio CO.,Ltd
Price USD200-USD300
Hits 797
Updated 3/26/2020
  • Product Detail
  • Company Profile

1. Usage

The FMDV Ab ELISA is a blocking Enzyme Linked Immunosorbent Assay for the qualitative detection of specific antibodies to Foot and Mouth Disease Virus (FMDV), in Swine ,bovine ,goat and sheep serum.

 

2. Principle

Porcine Foot And Mouth Disease(FMD) Type O antibody ELISA test kit is made from the antigen coated microtiter plate(coated) with FMD-O-VP1 antigen) and other reagents. It applies the Solid-phase ELISA principle to FMD-O-VP1-Ab in serum, then add enzyme conjugate to specifically bind with complex of coated antigen+FMD-O-VP1-Ab+enzyme labeled anti-pig-IgG antibody on the microplate. With the TMB substrate, it will generate an amount of color. The depth of color is relative with the content of the FMD-O-VP1-Ab, when the value of color is greater than the cut-off value, the pigs are vaccinated well or natural infected exist.

 

3. Materials Provided

 

Reagent

Volume

96 Tests/192Tests

1

 Antigen  coated micro-assay plate

 

1ea/2ea

2

 Negative Control

 

0.8ml/1.6ml

3

 Positive Control

 

0.8ml/1.6ml

4

 Sample  dilute solution

 

50/100ml

5

Washing solution (10X concentrated)

 

50/100ml

6

 Enzyme conjugate

6/11ml

7

 Color liquid 

 

11/22ml

8

Stopping solution

 

6/11ml

9

 Adhesive plate sealer

 

2ea/4ea

 

4Necessary equipment and reagents

1.  Micropipettor: 0.5µl-10µl、10µl-100µl、100µl-1000µl。

2.  Disposable pipette suction head

3.  Graduated cylinder:500ml。

4.  Enzyme mark with 96 microplate.

5.  Distilled water or deionized water

6.  Bottle washing machine

 

5. Collection and Storage of Sample

1) Fresh pig serum samples should be used for this assay. Hemolyzed or contaminated samples may give erroneous results.

2) If samples are not immediately tested, they should be refrigerated at 2~8℃. For longer storage, freeze the samples at -20℃ or below. Avoid repeated freezing and thawing.

3) Heat inactivated serum (for 30min at 56℃) is available.

 

6.Preparation of wash solution

Dilute the 10x wash solution by distilled/deionized water(1:9). Add 50㎖ of Wash solution to 450㎖of distilled/deionized water and mix thoroughly. Store at 2-8℃ or room temperature(18~25℃) after use.

 

7.Note

1. The kit should keep to room temperature and gentle shaking well before using.after using store  in temperature 2-8 ℃

2.Different varieties, different batch number kit reagent components shall not be mixed, should prevent reagent pollution when using reagent.

3. The substrate and terminate solution to skin and eyes might be irritating, should pay attention when using.

4. Color liquid not exposed to strong light and avoid contact with antioxidants.

5.Test plate after unpacking should avoid to be damp or touch water (the rest antigen package add desiccant in the self-styled bag, and placed 2-8 ℃ as soon as possible)

6. All waste before discarding should be reasonable processing to avoid pollution.

7. Strictly abide by the instructions you can get the best results.Move fluid, timing, washing, all the process must be accurate in the process

8. Serum dilution plate for disposable supplies, shall not be repeated use;Serum dilution plate of the maximum capacity of 300 mu l/hole

 

8. Procedure of the Test

1) Dilute the serum sample with sample dilution at 1:50,

2) 100 μl of negative control and positive control respectively, and 100 μl diluted samples each into remaining wells.

3) Cover the wells with plate sealer and incubate for 30 minutes at 37±1℃.

4) Remove all liquid from the wells and rinse the wells 4-6 times with 250㎕ of diluted wash solution. Remove any remaining wash solution by inverting the plate and blotting it against a clean paper towel.

5) Dispense 50㎕ of enzyme conjugate(ready to use) into each well.

6) Cover the wells with plate sealer and incubate for 30 minutes at 37±1℃.

7) Wash the wells as described above in Step 4.

8) Dispense 100㎕ of substrate(ready to use) to each well.

9) Cover the wells with plate sealer and incubate for 10 minutes at 37℃ in the dark.

10) Add 50 ㎕ of stopping solution(ready to use) to each well. Mix by gentle shaking.

11) Read the absorbance values of the wells at 450nm in a bichromatic spectrophotometer( with reference wavelength at 620nm) right after from the end of assay, within 10 minutes.

 

9. Interpretation of the Results

1) Test Validation

② The mean absorbance value of negative control(NCx) is < 0.2.

③ The mean absorbance value of Positive control(PCx) is > 0.5

④ If these values are out of range, result should be considered invalid and the samples should be retested.

2) Calculation of the Result

Criteria : The criteria is based on following formula.

 IRPC  = mean OD450 of sample- mean OD450 ofnegative /mean OD450 of Positive e control- mean OD450 of negative 

3) Interpretation of Results

The status of samples is determined as follows;

- IRPC≥ 0.4 is considered positive.

- IRPC < 0.4 is considered negative.

 

10. Stability and Storage

1) All reagents should be stored at 2~8℃. Do not freeze.

2) Shelf life is 12 months. Use all reagents before the expiry date on the kit. 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号