Login    Join free Add to favorites    中文
Home >Products> Incubators | Drying ovens >CO2 Incubators> CelCulture® CO2 Incubators
CelCulture® CO2 Incubators
CelCulture® CO2 Incubators
Origin of place Singapore
Model CelCulture® CO2 Incubators
Supplier ESCO
Price
Hits 2046
Updated 8/16/2024
  • Product Detail
  • Company Profile

Esco CelCulture CO2 incubators are widely used in scientific research to grow and maintain cell cultures. Typical fields of application include tissue engineering, in vitro fertilization, neuroscience, cancer research, stem cell research, regenerative medicine,  and other mammalian cell research.

Sleek, reliable and intuitive, Esco CelCulture CO2 incubators provide all-rounded sample protection that brings your scientific dreams one step closer to reality.

Key Benefits:

ULPA filtration system
90oC moist heat decontamination cycle, validated by HPA UK
Precise temperature and gas control

Features

VivoCell™ Precise Temperature, CO2 Control and High Humidity 
 

Best uniformity and control among competition
Fast CO2, temperature and humidity recovery without overshoot
Direct heat design for rapid recovery, with 8 heater grouped into 3 zones
Air jacket provides isolation against ambient temperature fluctuations
VentiFlow™ forced convection accelerates recovery of chamber air to ISO Class 5 Cleanliness after door closing to prevent contamination
Filtered air circulates across water pan to accelerate humidifying process
Air flows gently around culture plates, causing no disturbance to cell culture
Blower automatically stops when door is opened, to minimize mixing of chamber and room air
CelSafe™ Contamination Control System Provides Seamless Protection 

SteriSafe™ ULPA filtration enables the chamber air to be maintained at ISO class 5 condition.
SwiftCon™ moist heat 90oC decontamination cycle operates overnight to eradicate any contamination in the unlikely event it occurs. At the end of the cycle, the chamber is dry and ready to use.
All input gases are filtered by in-line filters before they enter the chamber to remove impurities and contaminants.
The incubator’s main body is made from electro-galvanized steel with Esco’s unique ISOCIDE antimicrobial coating.
The interior of the chamber is made from stainless steel type 304.
User-friendly software interface

Comprehensive user-configurable alarms for all the parameters.
CelAlert™ alarm system reminds user to replace CO2 tank and ULPA filter.
Intelligent data and event logger records all incubator parameters for on screen recall.
16 MB built-in flash memory guarantees long term storage of data.
Diagnostic interface and on line quick help provide comprehensive solutions to frequently. encountered problems.
RS485 data output.
Easy-to-Clean

Chamber is made of shiny stainless steel chamber with all rounded corners.
Ductwork, plenums and shelves are removable without tools.
Glass door is removable without tools.
Inner gasket removable without tools.
Easy-to-Service

Diagnostic functions in the microprocessor include historical read-out of the parameters.
Service can be carried out from the top/front
Esco electronics and sensors have been expertly designed and paired to be inherently drift-free, to minimize need for calibration

Models

TC Sensor Model With Stainless Steel Chamber

Models                Descriptions

CCL-050A-8          CelCulture® Incubator, 50L, TC Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ 
CCL-050A-9          CelCulture® Incubator, 50L, TC Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-170A-8          CelCulture® Incubator, 170L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-170A-8-NF     CelCulture® Incubator, 170L, TC Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ (No ULPA Filter)
CCL-170A-9          CelCulture® Incubator, 170L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ 
CCL-170A-9-NF     CelCulture® Incubator, 170L, TC Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ (No ULPA Filter)
CCL-240A-8          CelCulture® Incubator, 240L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-240A-8-NF     CelCulture® Incubator, 240L, TC Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ (No ULPA Filter)
CCL-240A-9          CelCulture® Incubator, 240L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-240A-9-NF     CelCulture® Incubator, 240L, TC Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ (No ULPA Filter)

IR Sensor Model With Stainless Steel Chamber

Models                Descriptions

CCL-050B-8          CelCulture® Incubator, 50L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ 
CCL-050B-9          CelCulture® Incubator, 50L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-170B-8          CelCulture® Incubator, 170L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-170B-8-NF     CelCulture® Incubator, 170L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ (No ULPA Filter)
CCL-170B-9          CelCulture® Incubator, 170L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ 
CCL-170B-9-NF     CelCulture® Incubator, 170L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ (No ULPA Filter)
CCL-240B-8          CelCulture® Incubator, 240L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-240B-8-NF     CelCulture® Incubator, 240L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ (No ULPA Filter)
CCL-240B-9          CelCulture® Incubator, 240L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-240B-9-NF     CelCulture® Incubator, 240L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ (No ULPA Filter)

Surpressed O2 Model With Stainless Steel Chamber

Models                Descriptions

CCL-050T-8          CelCulture® Incubator, 50L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ 
CCL-050T-9          CelCulture® Incubator, 50L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-170T-8          CelCulture® Incubator, 170L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-170T-8-NF     CelCulture® Incubator, 170L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ (No ULPA Filter)
CCL-170T-9          CelCulture® Incubator, 170L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ 
CCL-170T-9-NF     CelCulture® Incubator, 170L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ (No ULPA Filter)
CCL-240T-8          CelCulture® Incubator, 240L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-240T-8-NF     CelCulture® Incubator, 240L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ (No ULPA Filter)
CCL-240T-9          CelCulture® Incubator, 240L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-240T-9-NF     CelCulture® Incubator, 240L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ (No ULPA Filter)

IR Sensor Model With 100% Copper Chamber

Models                Descriptions

CCL-050B-8Cu      CelCulture® Incubator, 50L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ 
CCL-050B-9-Cu     CelCulture® Incubator, 50L, IR Sensor, CO2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-170B-8-Cu     CelCulture® Incubator, 170L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-170B-9-Cu     CelCulture® Incubator, 170L, IR Sensor, CO2 Control, ULPA
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-240B-8-Cu     CelCulture® Incubator, 240L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-240B-9-Cu     CelCulture® Incubator, 240L, IR Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ

Surpressed O2 Model With 100% Copper Chamber

Models                Descriptions

CCL-050T-8-Cu     CelCulture® Incubator, 50L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 230VAC 50/60HZ 
CCL-050T-9-Cu     CelCulture® Incubator, 50L, IR Sensor, CO2 Control, O2 Control,
                           Moist Heat Decon, 115VAC 50/60HZ
CCL-170T-8-Cu     CelCulture® Incubator, 170L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-170T-9-Cu     CelCulture® Incubator, 170L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ 
CCL-240T-8-Cu     CelCulture® Incubator, 240L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ
CCL-240T-9-Cu     CelCulture® Incubator, 240L, IR Sensor, CO2 Control, O2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ

CelMate® TC Sensor Model

Models                Descriptions

CLM-170A-8          CelMate® Incubator, 170L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ (Without Decon Pump)
CLM-170A-9          CelMate® Incubator, 170L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ (Without Decon Pump)
CLM-240A-8          CelMate® Incubator, 240L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 230VAC 50/60HZ (Without Decon Pump)
CLM-240A-9          CelMate® Incubator, 240L, TC Sensor, CO2 Control, ULPA,
                           Moist Heat Decon, 115VAC 50/60HZ (Without Decon Pump)

Accessories

Options
    •    COA-1001 : Humidity Display, Factory Installed
    •    COA-1001-F : Humidity Display, Field Install Kit
    •    COA-1002 : CO2 Backup (Tank Switcher), Factory Installed
    •    COA-1002-F : CO2 Backup (Tank Switcher), Field Installed
    •    COA-1004 : Reversed Door Swing, Factory Installed
    •    COA-1005 : Analog Outputs, Factory Installed
    •    COA-1005-F : Analog Outputs, Field Installed
    •    COA-1006 : Sealed Inner Door Kit  for 170L (4 Glass Doors With Latches), Factory Installed
    •    COA-1006-F : Sealed Inner Door Kit (4 Glass Doors With Latches), Field Installed
    •    COA-1007 : N2 Backup (Tank Switcher), Factory Installed
    •    COA-1007-F : N2 Backup (Tank Switcher), Factory Installed

Accessories
    •    COA-2018-F : Roll Base (50L)
    •    COA-2001-F : Roller Base (170L)
    •    COA-2019-F : Roller Base (240L)
    •    COA-2020-F : Floor Stand 200mm (8.0") With Adjustable Feet (50L)
    •    COA-2002-F : Floor Stand 200mm (8.0") With Adjustable Feet (170L)
    •    COA-2021-F : Floor Stand 200mm (8.0") With Adjustable Feet (240L)
    •    COA-2022-F : Floor Stand 700mm (27.6") With Casters (50L)
    •    COA-2003-F : Floor Stand 700mm (27.6") With Casters (170L)
    •    COA-2023-F : Floor Stand 700mm (27.6") With Casters (240L)
    •    COA-2005-F : 2-Stage Gas Regulator for CO2/N2
                                  Choose One of The Connectors Below: 
                                  1080588 - CGA 320 Connector (US Standard)
                                  1080589 - BP-BS34-#8-NT4 Connector (British Standard)
                                  1080590 - G5/8-RH Connector (China Standard)
    •    COA-2024-F : Extra Shelf (50L, Stainless Steel)
    •    COA-2007-F : Extra Shelf (170L, Stainless Steel)
    •    COA-2025-F : Extra Shelf (240L, Stainless Steel)
    •    COA-2008-F : Stacking Kit (One Set Included With Every Unit Purchased) 
    •    COA-2010-F : Electronic CO2 Analyzer, For CO2/O2 Temp Measurement (With Temp. Probe)
    •    COA-2016-F : Electronic CO2 + O2 Analyzer, For CO2/O2 Temp Measurement (With Temp. Probe)
    •    COA-2017-F : Electronic CO2 + O2 + RH Analyzer, For CO2/O2/RH/Temp Measurement
                               (With Temp. Probe)
    •    COA-2011-F : IQ/OQ Documentation
    •    COA-2012-F : 6" Chart Recorder, Temp, 115/230VAC 50/60HZ
    •    COA-2013-F : 8" Chart Recorder, Temp/Temp, 115/230VAC 50/60HZ
    •    COA-2014-F : 6" Chart Recorder, Temp/RH, 115/230VAC 50/60HZ
    •    COA-2015-F : Inner Door Shelving Kit (4 Sets With Total 12 Mini Shelves For One Incubator)
    •    COA-2026-F : Extra Shelf (50L, Solid Copper)
    •    COA-2027-F : Extra Shelf (170L, Solid Copper)
    •    COA-2028-F : Extra Shelf (240L, Solid Copper)
    •    5250001 : Voyager Software Kit

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号