Main Features:
This versatile linear/convex ultrasound system is ideal for wide applications. Weighting only 2kg, it is distinguishable by its clear image quality, wide choices of probes for different diagnostic applications, complete software packages, and user-friendly design.
Technical Specification:
Scanning Method: Convex, Micro-convex, Linear, endorectal
Display Mode: B,B+B,B+M,M
Gray Scale:256 levels
Monitor Size:10.4" TFT color LCD
Image Procession: DFS,DRF,RDA,VGA/DSC and image pre & post
Cine-memory:206 frames (human),256 frames(vet)
32 image permanent storage
Image magnification: ×1.0,×1.2,×1.5,×2.0 times
Multi-step Zoom (1:2) in both real-time and frozen modes
Focusing selectable
Depth adjustable in real-time of B and B+B mode
Image Conversion is U/D,L/R and B/W.
8 different coded-color on a external color monitor
15 different kinds of body marks
Measurement is in Distance ,Circumference/Area, Heart Rate、EF rate for heart, and GS,CRL,BPD,HC,FL,AC for OB/GY measurement, and Gestational Age, Fetal weight, EDD calculation.
Characteristic showing in real-time clock, ID, Sex, Age, Focusing info and Hospital Name
Standard configuration:
main unit + 7.5MHz endorectal probe
bio-equip.cn
HONGKONG LIHUA ELECTRONIC TECHNOLOGY DEVELOPMENT CO., LIMITED is specialized in the production and sales of research experiments microcirculation, using SDF technology (sidestream darkfield imaging (SDF), sidestream dark field (SDF) imaging ), the observed changes in special parts of the animal and human blood. observe the special parts of the animal or human blood flow changes.
The condition of the blood vessels and blood of experimental animals can provide for the animal experiments, in order to cardiovascular disease in experimental animals blood poisoning、sepsis and failure early noninvasive monitoring and scientific data, and provide scientific data for the human disease.
Product: sublingual microcirculation (lingua microcirculation,tongue microcirculation, cerebral microcirculation, renal microcirculation ,visualize the microcirculation at the bedside and sidestream dark field (SDF) handheld imaging device (Microvascular (blood) image observation instrument) etc.
Its technical characteristics are as follows:
(1) Use SDF technology, can observe animal or person special parts such as the tongue, kidney and other parts of the blood flow changes.
(2)can provide the number of capillaries, vascular caliber and velocity, TVD / PVD, PPV, / MFI of experimental animals of data , and so on .
(3) equipment with convenience, can be carried out directly noninvasive observed in the laboratory experiments bedside characteristics, operation is simple.
|