LH-9618FV Digital signals
Main Features:
10 inch VGA monitor
Four probes acceptable: convex, linear, transvaginal and endorectal
3 step multi-frequency
Measurement: Distance, circumference, area, volume, EF rate, heart rate
OB measurement: GA, BL, SL, HL, HD, BD, CRL
4-step zooming: x1.0, x1.2, x1.5, x2.0 with scroll-up depth control
1 probe connector(standard), can be updated to 2-probe connectors.
(Optional)
Technical Specification :
Scanning mode: Convex/Linear
Display modes: B,B+B,B+M,M
Scanning depth: 220mm
Gray scales: 256
Cine-loop: 511 frames (Max)
Image permanent storage: 32 frames
Image magnification: ×1.0,×1.2,×1.5,×2.0
Image conversion: up/down, left/right, black/white
Zoom: 2 times both in real-time and frozen
Frame correlation: Three levels to adjust (B、B+B mode)
Electronic focuses: 4-sector dynamic
Depth scroll up in B and B+B modes
Resolution Lateral:≤2mm, axial≤1mm
Body marks: 15
Measurement: Distance, circumference ,area, heart rate, EDD
Comment : date , name , sex, age , hospital , annotation
Coded-colors : 7
Video output: PAL-D , ACE , Noninterlace , VGA
Monitor: 10 inch VGA
Power Supply: 100V~130V/220V~240V, 50/60Hz
Weight: 11.5 Kg(including probe)
Dimensions(mm): 353Χ315Χ253
Packing dimensions(mm):430×390×410
Standard configuration:
C1-2/60R/3.5MHz Multi-freq Convex Probe
bio-equip.cn
HONGKONG LIHUA ELECTRONIC TECHNOLOGY DEVELOPMENT CO., LIMITED is specialized in the production and sales of research experiments microcirculation, using SDF technology (sidestream darkfield imaging (SDF), sidestream dark field (SDF) imaging ), the observed changes in special parts of the animal and human blood. observe the special parts of the animal or human blood flow changes.
The condition of the blood vessels and blood of experimental animals can provide for the animal experiments, in order to cardiovascular disease in experimental animals blood poisoning、sepsis and failure early noninvasive monitoring and scientific data, and provide scientific data for the human disease.
Product: sublingual microcirculation (lingua microcirculation,tongue microcirculation, cerebral microcirculation, renal microcirculation ,visualize the microcirculation at the bedside and sidestream dark field (SDF) handheld imaging device (Microvascular (blood) image observation instrument) etc.
Its technical characteristics are as follows:
(1) Use SDF technology, can observe animal or person special parts such as the tongue, kidney and other parts of the blood flow changes.
(2)can provide the number of capillaries, vascular caliber and velocity, TVD / PVD, PPV, / MFI of experimental animals of data , and so on .
(3) equipment with convenience, can be carried out directly noninvasive observed in the laboratory experiments bedside characteristics, operation is simple.
|