Login    Join free Add to favorites    中文
Home >Products> Clean Benches | Biosafety | Sterilizers >Ultrasonic Cleaner> Medical ultrasonic washer dental washer
Clean Benches | Biosafety | Sterilizers:  Clean Benches   Biosafety Cabinets   Autoclaves / Sterilizers   Fume Hood   Ultrasonic Cleaner  
Medical ultrasonic washer dental washer
Medical ultrasonic washer dental washer
Origin of place China
Model KMH1 series
Supplier Guangdong GT Ultrasonic Industrial Co.,Ltd
Price $880-6888
Hits 946
Updated 6/23/2014
  • Product Detail
  • Company Profile

Features

1.Frequency: 40Khz
2.Temperature: 0 to 65°C
3.Ultrasonic power adjustable from 20-100%
4.Timer: 1-99 infinite loop
5.Sweep frequency capability
6.Soundproof design, more quiet
7. Safe and steady PCB
8.Industrial grade IC with powerful ultrasonic transducer
9.Working frequency LCD display
10. Working temperature LCD display
11. Working time LCD display
12. Memory setting function
13. The whole machine made of stainless steel
14. spray-paint in size 15L/20L/30L for choice
 
Application
Use in hospital to cleaning ,sterilize and dry the scalpel, tweezers, hemostatic forceps、endoscopic biopsy forceps, needles, various size syringe, tube, sheet glass, dressing bowl, all kinds of dishes, round barrel, pressure apparatus and radioactive, polluting, high-volume, nobleness degree medical equipment cleaning, sanitizing etc. The necessary equipment for operating, supply room and disinfection center of hospital , R&D institution, laboratory.
 

Gynaecology instruments:

Apart from blood, other endogenic fluids also dry quickly on specula. It has been noted that they are very difficult to remove manually. Therefore, instruments and accessories from gynaecology should principally be prepared with especially efficient mechanical cleaning procedures.

Certain mucous disinfectants fix proteins and cause corrosion. These can be replaced with halide-free and non-fixing preparations.

Orthopaedics instruments:

Bone cement is very difficult to remove and often only completely by means of an alkaline RDG (cleaning and disinfectant devices) procedure after drying.

Bone cement must be wiped off the instruments immediately after use in the operation theatre, for example, bone rasps can be freed of splinters in an ultrasound bath.These splinters can be dragged into the machine clogging up the jet spray arms and thus reduce the rinsing pressure. Particular attention should be shown to  intramedullary reamers and screws. The manufacturers generally provide important advice in the operating instructions according to DIN EN ISO 17664, about how the overall quality of the decontamination can be ensured by a targeted, short manual clean.

ENT instruments:

In the ENT area, ointments often make reprocessing more difficult. They should be wiped off immediately and as completely as possible after the application in the operating theatre.

MIS instruments:

Despite receptacle containers, a manual preparation – e.g. with special brushes – is often required. Instruments which cannot be dismantled or devices without rinsing connections cannot be safely decontaminated according to today’s standards and should not be used.

Mono- and bipolar instruments:

These instruments routinely adhere with coagulated blood and tissue which cannot be removed in a mechanical preparation. Soaking the tips in 3 % hydrogen peroxide solution, or very strong alkaline prodcuts is recommended for manual decontamination. Where necessary the tips should be wiped to remove excess product. 

Eye instruments:

Ophthalmic surgical instruments are often very sensitive due to their filigree structure. Thus, a manual clean is not possible in most of the cases.According to the latest legal requirements (Guideline of the Robert Koch Institute and ISO 17664),the manufacturer of these products must define at least one automatic and validated procedure for their decontamination.

The procedure must include, among others, details on validated processes for safe cleaning, disinfection and sterilisation. Due to the sensitivity of the eyes, it is vital to make sure, e.g. by measuring chemical parameters, that no process chemicals have remained on the tools to be prepared.

The ideal situation for CSSD would be to work closely with the operating theatres. This cooperation ensures that everyone is involved and understands which measures are used for the “drop” in order to aid the next steps of decontamination. The instructions and recommendations of the instrument manufacturer should strictly be observed.

 
Specifications
KMH1-360W9152     15   480×500×530      355×325×150      360  300
KMH1-720U9202        20   560×500×530      530×325×150      600  500
KMH1-1100U9302       30   560×500×530      530×325×200      720     500
KMH1-1200U9502      50   750×550×860      600×400×210      1080      1000
KMH1-1440U9722      72   810×600×860      660×450×240      1440      1000
KMH1-1680U9962      96   850×630×860      700×480×300      1800      1500
KMH1-2160U0122      120 850×630×860      700×480×350      2160      2000
KMH1-1100W0122      144 850×650×910      700×500×400      2400      3000
KMH1-1440W0122     200 900×750×960      750×600×450      2880      4000
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号