Login    Join free Add to favorites    中文
Home >Products> Clean Benches | Biosafety | Sterilizers >Autoclaves / Sterilizers> Vertical Pulse Vacuum Autoclave
Clean Benches | Biosafety | Sterilizers:  Clean Benches   Biosafety Cabinets   Autoclaves / Sterilizers   Fume Hood   Ultrasonic Cleaner  
Vertical Pulse Vacuum Autoclave
Vertical Pulse Vacuum Autoclave
Origin of place China
Model https://www.scitekglobal.com/
Supplier Scitek Global Co.,Ltd
Price info@scitekglobal.com
Hits 33
Updated 4/1/2025
  • Product Detail
  • Company Profile

Vertical Pulse Vacuum Autoclave Features:

  1. Overheat protection: Automatically cutting off heating with audible and visual indication when the autoclave is overheated.

  2. Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.

  3. Interlock safety: Preventing from starting a cycle if door is not properly closed or from door opening if there is pressure inside chamber.

  4. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.

  5. Automatic operation from sterilization to drying (Pre-vacuum sequence, heating, sterilization, steam discharge and post-vacuum drying) can be easily set and monitored by the LCD touch screen

  6. Built-in vacuum pump provides 3-time pulsed vacuum process,extracting the air out of the medical dressing and the Class A hollow medical instrument efficiently.

  7. Built-in steam generator prevents the media from contamination.

  8. Post-vacuum drying function offers efficient drying results.

  9. Positive pulsing function removes the air efficiently.

  10. With 0.22µm air filter, blocks all microorganisms from exiting the chamber during the air removal phase.

  11. Standard built-in printer.

  12. Optional real-time record sterilization process, error and alarm information.

Vertical Pulse Vacuum Autoclave Specifications:

Model ST-V50PV ST-V80PV ST-V100PV ST-V120PV ST-V150PV
Capacity 50L 80L 100L 120L 150L
External Size (WxDxH)(mm) 580x636x990 636x710x1030 630x710x1295 700x780x1190 780x850x1180
Chamber Size (ØxH)(mm) Ø316x667 Ø386x695 Ø386x860 Ø450x760 Ø500x780
Chamber Material SUS304
Sterilization Temperature 105~136 ℃
Designed Temperature 150℃
Max. Working Temperature 136 ℃
Dissolution Temperature 40~100℃
Warming Temperature 40~60℃
Temp.Accuracy 0.1℃
Temp. Uniformity ≤±0.5℃
Designed Pressure 0.3Mpa
Max.Sterilization Pressure 0.23Mpa
Ultimate Vacuum -0.096MPa
Pressure Resoluiton 0.1KPa
Sterilization Time Range 0~99min
Temp. Controller PID control by microprocessor
Display LCD touch screen
Drying Function YES
Drying Time 15min
Sterilization Program ●Medical instrument program
●Luminal instruments
●Dressings/Fabric program
●Rubber program
●Liquid program
●BD Test program
●Vacuum Test progrm

Sterilization of medical dressing, medical Instruments, Instruments with cavity, Rubber,

liquids plus 4 user-customized programs BD Test and vacuum test.

Water Injection Method Built-in water tank
Power Consumption 3KW 4.5KW 5.4KW 7.2KW 9.3KW
Power Supply 220V 50Hz 220V 50Hz 220V 50Hz 380V 50Hz 380V 50Hz
Standard SS Basket 2pcs 2pcs 2pcs 2pcs 2pcs
Net Weight 85kg 95kg 112kg 180kg 210kg
Gross Weight 122kg 130kg 152kg 220kg 250kg
Shipping Size (WxDxH)(mm)

840x770x1170

880x910x1300

880x910x1550

1030x1050x1300

1030x1050x1450

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel: