|
Streamline® Polymerase Chain Reaction Cabinets
Origin of place |
Singapore  |
Model |
Streamline® Polymerase Chain Reaction Cabinets |
Supplier |
ESCO |
Price |
|
Hits |
1371 |
Updated |
8/16/2024 |
|
Polymerase Chain Reaction* (PCR) is a process where millions of copies of DNA are amplified from a single copy, or low copy number template. This reaction is fundamental to almost all applications requiring high copy number of starting material and is used in all laboratories working with DNA and RNA. Because of the high copy number that is generated during PCR, it is absolutely essential to prevent contamination of the PCR reaction.
In addition to good laboratory practice, the ideal PCR laboratory should consist of three areas, each isolated from the other. Reagents should be prepared in the reagent preparation area and transferred to the sample preparation area, through a pass box, or inside closed containers. After preparation of the final reaction mix, the tubes should be transferred to the amplification area, again through a pass box or in a closed container. The PCR amplification and results analysis takes place in this area. To guarantee contaminant-free samples, it is essential to work in an environment where the air quality is controlled, such as a PCR clean bench, vertical laminar flow or biological safety cabinet.
Key Benefits:
•HEPA-filtered laminar flow
•Cost & space saving
•Simple & Reliable operation
Features
•True vertical laminar airflow with a large filter covering the entire work zone within the cabinet for better protection against cross contamination, as compared to conventional dead-air boxes.
•High-quality polyurethane pre-filter and main HEPA filter with a typical efficiency of >99.99% at 0.3 microns provide the best product protection in the world; typical HEPA filter lifespan is more than 3 years depending on ambient operating conditions and total number of hours in usage.
•A powerful 253.7 nanometer 20-watt UV lamp is placed behind the front panel out of the operator's direct line of sight, ensuring maximum operator comfort and safety; This unique placement design eliminates "dead zones" and ensures all exposed interior surfaces are decontaminated effectively.
•Easily accessible adjustable UV-timer (from 0 - 60 minutes) for precise decontamination cycle control.
•Integral safety cover (constructed of 5mm / 0.2" UV-absorbing beta radiation resistant polycarbonate - superior to conventional materials such as acrylic) with two operating positions; fully open (self-supporting with spring hinges) during normal use & fully closed during UV decontamination of interiors.
•Effective safety features to prevent operator exposure to harmful UV rays; interlock system ensures UV lamps do not activate unless safety cover is closed; in case the cover is accidentally opened the UV lamps will also automatically deactivate.
•Built-in warm white, 5.000k electronically ballasted lighting offers excellent illumination throughout the work zone in order to reduce operator fatigue and is comfortable to the eyes. Light tubes are mounted out of the air stream for better airflow uniformity.
Models
Model No. |
External
Dimensions (mm) |
Internal
Dimensions (mm) |
Airflow
Velocity (Inflow) |
Airflow
Velocity (Downflow) |
Electrical |
SCR-2A1 |
730 x 617 x 950 |
630 x 538 x 550 |
- |
0.275 - 0.325(m/s) /
54-64(fpm) |
220-240V,AC, 50Hz,1ø |
SCR-2A2 |
110-120V,AC, 60Hz,1ø |
SCR-2A3 |
220-240V,AC, 60Hz,1ø |
Certification
STANDARDS COMPLIANCE |
CABINET PERFORMANCE |
AIR QUALITY |
FILTRATION |
ELECTRICAL SAFETY |
IEST-RP-CC002.2, Worldwide |
ISO14644.1 Class 3, Worldwide
AS1386 Class 1.5, Australia
JISB9920 Class 3, japan |
IEST-RP-CC034.1, Worldwide
IEST-RP-CC007.1, Worldwide
IEST-RP-CC001.3, Worldwide
EN1822 (H13), Europe |
IEC61010-1, Worldwide
EN61010-1, Europe
UL61010-1, USA
CAN/CSA-22.2, No.61010-1 |
bio-equip.cn
At Esco, we realise that quality and customer satisfaction are our top priorities. Extensive quality control and testing is carried out at all steps of the design and production process. Our factory is independently audited regularly by inspectors from certification agencies around the world. All 220-240VAC 50HZ products are CE-marked
Innovative Products
In every Esco product you will find thoughtful designs which are the product of more than 25 years of experience in designing and manufacturing clean air and containment equipment. Extensive investments are continuously made in research and development technology. In-house performance testing is also conducted continuously to further improve product performance and safety.
Global Reference List
Esco products have also been validated today by users from many different fields of science and industry, in more than 60 countries globally.
Investments in Human Resources
Extensive investments in human resources and recruiting the best minds enable us to develop creative solutions and designs. Our staff are equipped with a wide variety of technical resources and facilities at their disposal. In fact, half of all non-production staff at Esco work in an research and development related position.
|
|
|