AELAB Biosafety Cabinets and Biological Containment Solutions

AELAB supplies a broad range of biological safety cabinets designed to support personnel protection, sample protection and environmental contamination control in microbiology, biotechnology, pharmaceutical, clinical, research and industrial laboratories.

The available product family includes Class II Type A2 and Class II Type B2 biological safety cabinets, NSF-certified and EN-certified configurations, compact cabinets, double-sided models, cytotoxic safety cabinets and specialized containment solutions for different laboratory workflows.

Customers can compare AELAB biosafety cabinet models according to cabinet class, airflow configuration, exhaust requirements, workspace size, containment level, certification preference and intended laboratory application.

Explore AELAB Biosafety Cabinet Models

Review available Class II A2, Class II B2, certified and specialized biological safety cabinet configurations.

View All AELAB Biosafety Cabinets

Request Model Recommendation and Quotation


Available Biosafety Cabinet Types
Cabinet Type Typical Application
Class II Type A2 Biosafety Cabinet Used for biological and microbiological procedures requiring protection of the operator, working material and surrounding laboratory environment.
Class II Type B2 Biosafety Cabinet Designed for higher-containment workflows requiring externally exhausted air and no cabinet air recirculation.
NSF-Certified Biosafety Cabinet Selected for laboratories that require cabinet configurations evaluated according to applicable NSF biological safety cabinet requirements.
EN-Certified Biosafety Cabinet Suitable for laboratories specifying cabinet designs evaluated according to applicable European biological safety cabinet requirements.
Double-Sided Biosafety Cabinet Provides access from two sides for selected workflows, production layouts or laboratory processes requiring material transfer between controlled areas.
Compact Biosafety Cabinet Designed for laboratories with limited installation space or lower-volume biological handling requirements.
Cytotoxic Safety Cabinet Developed for controlled preparation and handling workflows involving cytotoxic or hazardous pharmaceutical materials, subject to the selected cabinet configuration.
Specialized Biological Containment Cabinet Used for application-specific laboratory protection, biohazard handling and specialized research or clinical workflows.

Main Protection Functions
Personnel Protection

Controlled inward airflow helps reduce operator exposure to airborne biological contaminants generated inside the working area.

Product Protection

Filtered downflow supports a cleaner working zone and helps reduce contamination of samples, cultures, reagents and laboratory materials.

Environmental Protection

Filtered exhaust airflow helps limit the release of airborne biological contaminants from the cabinet into the surrounding laboratory.


Typical Laboratory Applications
  • Microbiology culture handling and sample preparation
  • Clinical and diagnostic laboratory procedures
  • Cell culture and tissue culture workflows
  • Biotechnology research and biological material handling
  • Pharmaceutical microbiology and quality control
  • Preparation of sterile biological samples and reagents
  • Hospital, pathology and biomedical research laboratories
  • Food and beverage microbiological testing
  • Environmental microbiology and water testing laboratories
  • Veterinary, agricultural and animal health laboratories
  • Biological sample processing in universities and research institutes
  • Selected cytotoxic drug preparation and pharmacy workflows

Class II A2 and Class II B2 Cabinet Comparison
Comparison Item Class II Type A2 Class II Type B2
Airflow Arrangement A portion of filtered air is generally recirculated within the cabinet, with the remaining air exhausted. Cabinet air is exhausted without recirculation into the working area.
Exhaust Connection The required exhaust arrangement depends on the model, application and laboratory installation. Normally requires connection to a suitable external exhaust system.
Typical Selection Common biological work, microbiology, cell culture and routine contamination-control procedures. Selected higher-containment procedures and applications requiring full cabinet exhaust.
Facility Planning Usually provides greater installation flexibility, depending on the selected configuration. Requires careful coordination with the building ventilation and exhaust design.

How to Select the Right Biosafety Cabinet

Selecting a biosafety cabinet should begin with a documented risk assessment. The laboratory should evaluate the biological agents being handled, required protection level, use of volatile substances, exhaust conditions, cabinet certification requirements and available installation space.

Selection Factor Questions to Consider
Cabinet Class and Type Does the procedure require a Class II A2, Class II B2 or another specialized containment configuration?
Biological Risk What microorganisms, cultures, clinical samples or biological agents will be handled inside the cabinet?
Personnel and Product Protection Does the workflow require simultaneous protection of the operator, sample and surrounding environment?
Exhaust Configuration Is an external exhaust connection available, and can the facility support the airflow requirements of the selected cabinet?
Working Width How many operators, containers, instruments and sample racks must fit inside the working area?
Certification Preference Does the laboratory require an NSF-certified, EN-certified or application-specific cabinet configuration?
Installation Space Are the room dimensions, ceiling height, doorway clearance and service access suitable for installation?
Cabinet Placement Can the cabinet be positioned away from doors, strong air currents, ventilation outlets and high-traffic areas?
Cleaning Requirements Does the working chamber provide suitable access and surfaces for routine cleaning and decontamination?
Service and Certification Is local installation support, airflow testing, filter service and periodic cabinet certification available?

Representative AELAB Biosafety Cabinet Families
AELAB Class II A2 Biological Safety Cabinet Series

A broad family of Class II A2 cabinets intended for biological handling procedures requiring operator, product and environmental protection. Available product groups include the EA2, EC, AC, BSC, Pro and BBC86-related series.

AELAB Class II B2 Biological Safety Cabinet Series

Designed for applications requiring full exhaust operation and no recirculation of cabinet air. Available families include the EB2, AC and BSC Pro series, along with selected high-containment configurations.

AELAB NSF-Certified Biosafety Cabinet Series

Includes selected Class II A2 and Class II B2 configurations developed for laboratories specifying NSF-certified biological safety cabinet solutions.

AELAB EN-Certified Biosafety Cabinet Series

Available for laboratories requiring selected biological safety cabinet configurations designed around applicable European certification requirements.

AELAB Compact and Double-Sided Biosafety Cabinets

Includes compact cabinets for laboratories with limited available space and double-sided models such as selected BSC-1500IIA2-S configurations for specialized laboratory layouts.

AELAB Cytotoxic and Specialized Safety Cabinets

Specialized cabinet solutions are available for controlled drug preparation, cytotoxic material handling and other application-specific biological containment requirements.

AELAB BYKG Biological Safety Cabinet Series

A dedicated biological safety cabinet family for laboratory protection, available in multiple configurations according to the selected model and application.

View the complete AELAB biosafety cabinet range, available models and technical information


Installation and Operating Considerations
  • Select the cabinet type only after completing an application and biological risk assessment.
  • Confirm room dimensions, doorway dimensions and delivery access before ordering.
  • Keep the cabinet away from doors, open windows, strong ventilation currents and busy walkways.
  • Verify external exhaust compatibility when selecting a Type B2 cabinet.
  • Do not block the front or rear airflow grilles during operation.
  • Keep the internal workspace organized and avoid unnecessary equipment or materials.
  • Clean the work surface before and after laboratory procedures.
  • Arrange cabinet inspection and performance certification according to laboratory procedures and applicable requirements.
  • Consult qualified personnel before relocating, modifying or connecting the cabinet to building ventilation.

Biosafety Cabinet Compared with Other Laboratory Enclosures
Laboratory Enclosure Primary Purpose Typical Use
Biosafety Cabinet Biological containment and protection of personnel, samples and the environment. Microbiology, clinical samples, cell culture and other biological procedures.
Laminar Flow Cabinet Protection of clean products or samples from external contamination. Non-hazardous sterile preparation where operator biohazard protection is not required.
Fume Hood Protection of the operator from chemical fumes, vapors and gases. Chemical handling, acid digestion, solvent work and other hazardous chemical procedures.
PCR Cabinet Reduction of contamination during pre-PCR reagent and sample preparation. Clean preparation of PCR master mixes, reagents and nucleic-acid workflows without biohazard containment requirements.


Why Consider AELAB Biosafety Cabinets?
  • Multiple Class II A2 and Class II B2 cabinet families
  • Solutions for routine biological work and higher-containment applications
  • NSF-certified and EN-certified options within selected product families
  • Compact, standard-width, double-sided and specialized configurations
  • Cabinets for microbiology, pharmaceutical, clinical and research laboratories
  • Model-selection support based on application and installation conditions
  • Technical specification and quotation support before ordering
  • International supply, export packaging and shipping support
  • Configuration and power-supply options according to model availability
About AELAB

AELAB is a laboratory equipment brand and supplier based in Guangzhou, China. The company supplies analytical instruments, laboratory equipment, environmental testing systems, life science equipment and quality-control solutions for distributors, universities, research organizations and industrial customers.

The AELAB range includes biosafety cabinets, laminar flow cabinets, fume hoods, PCR cabinets, laboratory analytical instruments, sample preparation systems and other laboratory solutions.

Official website: www.aelabgroup.com


Frequently Asked Questions

What types of biosafety cabinets does AELAB supply?

AELAB supplies Class II A2 and Class II B2 biological safety cabinets, along with selected NSF-certified, EN-certified, compact, double-sided, cytotoxic and specialized cabinet configurations.

What is the difference between a Class II A2 and a Class II B2 cabinet?

A Class II A2 cabinet normally recirculates a portion of filtered air, while a Type B2 cabinet exhausts cabinet air and normally requires a suitable external exhaust connection.

Is a biosafety cabinet the same as a laminar flow cabinet?

No. A biosafety cabinet is designed for biological containment and operator protection, while a laminar flow cabinet mainly protects non-hazardous samples or products from contamination.

Can a biosafety cabinet replace a chemical fume hood?

Not generally. Chemical fume hoods and biosafety cabinets are designed for different hazards. The correct enclosure must be selected according to the chemicals, biological agents and procedure involved.

Are certified AELAB biosafety cabinet models available?

Yes. The AELAB category includes selected NSF-certified and EN-certified biological safety cabinet product families. The exact certification and documentation should be confirmed for the required model before ordering.

What information is needed for model selection?

Provide the intended application, biological material, required cabinet class, preferred working width, exhaust availability, certification requirements, destination country and laboratory installation conditions.

Can AELAB recommend a suitable biosafety cabinet?

Yes. The AELAB team can review the application and installation requirements, recommend suitable cabinet models and provide technical specifications and a quotation.

Request Biosafety Cabinet Recommendation, Price and Technical Proposal

Tell the AELAB technical sales team which biological materials will be handled, the required cabinet class, workspace width, exhaust conditions, certification preference and destination country.

The quotation can include recommended models, technical specifications, available configurations, optional accessories, delivery time, packaging and shipping information.

View AELAB Biosafety Cabinet Models

Email: info@aelabgroup.com

WhatsApp / WeChat: +86 158 0001 6110

Website: www.aelabgroup.com

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2026 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号