67M is a powerful, reliable professional portable water quality testing photometer, with our reagents, it can measure 67 items of the water quality, for example, it can measure COD in water, the water quality testing photometer also can measure the heavy metal such as Lead in water. In-set a number of parameters, simple operation, fast testing, It is widely used in water supply, environmental protection, public health, water treatment and other areas of the wild field, on-site water testing and treatment in emergencies.
Features&Advantage
1. Simultaneous support for colorimetric bottle and digestion tube detection mode, intelligent matching of built-in standard curve.
2. Support more than 7 wave lengths with intelligent software control and switch the wavelength automatically.
3. Over 67 default test procedures, supporting doing test directly with special reagent kit.
4. Support USB and PC connection, large capacity memory with 1,000 groups of data.
Optional intelligent safe Reactor:
1.The integrated explosion-proof feature and double lock provide additional safety; 2.Independent design make the reactor more easy to clean and maintain,its corrosion-proof,high temperature resistant material.
3.Variable frequency heating temperature control is more accurate.
Specification
Wavelength
|
Default wavelength: 380nm, 420nm, 470nm, 520nm, 600nm,
620nm, white light, can be extended wavelength
|
Display
|
3.5 inch TFT colorful screen display
|
Precision
|
≤3%
|
Resolution
|
0.001A (display); 0.0001A (calculation)
|
Memory
|
Supporting 1,000 groups of data and PC data management
software
|
Power supply
|
4 AA batteries or USB supply
|
Test items
|
CODcr (LR), CODcr (HR),nitrite, nitrate,total phosphorus total nitrogen , pH, color, turbidity, free chlorine, total chlorine, combined chlorine, chlorine dioxide, chlorite, ozone (DPD),
ozone (indigo France), oxygen consumption,ect 68 parameters
|
Reactor specification
|
6 digestion holes, Depth 65mm, Round hole bottom
|
Reactor efficiency
|
10 minutes from 25 ° C to 150 ° C
|
indication error
|
±2°C
|
67M Muti-Parameter Photometer
|
NO
|
Method
|
Items
|
Range(ppm)
|
Resolution
|
Precision
|
1
|
Potassium permanganate spectrophotometery
(acidity)
|
COD
(acidity)
|
0.1-5.0 ppm
|
0.1ppm
|
≤10%±0.1
|
2
|
N,N-diethyl-p- phenylenediamine
spectrophotometery
|
Sulfide
|
0.02-1.00ppm
|
0.01ppm
|
≤5%±0.01
|
3
|
Iodine
spectrophotometry
|
Dissolved
oxygen
|
0.20-15.00ppm
|
0.1ppm
|
≤3%±0.1
|
4
|
Isonicotinic acid- barbituric Acid spectrophotometery
|
Cyanide
|
0.002~
0.400ppm
|
0.001ppm
|
≤3%±0.001
|
5
|
DPCI
spectrophotometery
|
Hexavalent
chromium
|
0.004~1.500pp
m
|
0.001ppm
|
≤3%±0.001
|
6
|
Potassium permanganate oxidation - DPCI spectrophotometry
|
Total chromium
|
0.01~2.00ppm
|
0.01ppm
|
≤3%±0.01
|
7
|
Mercury(II) thiocyanate spectrophotometry
|
Choride
|
0.2~20.0ppm
|
0.1ppm
|
≤3%±0.1
|
8
|
Chrome azurol S spectrophotometry
|
Aluminum
|
0.008~0.250pp
m
|
0.001ppm
|
≤3%±0.001
|
9
|
Indigo
spectrophotometery
|
Ozone(I)
|
0.01~0.50ppm
|
0.01ppm
|
≤3%±0.01
|
10
|
DPD
spectrophotometry
|
Ozone(II)
|
0.01~10.0ppm
|
0.01ppm
|
≤3%±0.01
|
11
|
Diazo coupling
spectrophotometery
|
Nitrite
|
0.003~
0.500ppm
|
0.001ppm
|
≤3%±0.001
|
12
|
Nessler reagent spectrophotometery
|
Ammonia nitrogen(fresh
water)
|
0.02~60.0ppm
|
0.01ppm
|
≤3%±0.01
|
13
|
DPD
spectrophotometry
|
Free chlorine
|
0.01~5.00ppm
|
0.01ppm
|
≤3%±0.01
|
14
|
DPD
spectrophotometry
|
Total chlorine
|
0.01~5.00ppml
|
0.01ppm
|
≤3%±0.01
|
15
|
DPD
spectrophotometry
|
Chlorine
dioxide
|
0.02~10.00ppm
|
0.01ppm
|
≤3%±0.01
|
16
|
DPD
spectrophotometry
|
Chlorite
|
0.00~2.00ppm
|
0.01ppm
|
≤3%±0.01
|
17
|
DPD
spectrophotometry
|
Combined
chlorine
|
0.01~5.00ppm
|
0.01ppm
|
≤3%±0.01
|
18
|
DPD
spectrophotometry
|
Active oxygen
|
0.005~1.000pp
m
|
0.001ppm
|
≤3%±0.001
|
19
|
Naphthisodiazine
spectrophotometery
|
Ferrum
|
0.10~3.00ppm
|
0.01ppm
|
≤5%±0.01
|
20
|
Formaldoxime spectrophotometery
|
Manganese
|
0.03~
5.00mg/L
|
0.01ppm
|
≤5%±0.01
|
21
|
Thymol
spectrophotometery
|
Nitrate
|
0.5~15.0ppm
|
0.1ppm
|
≤3%±0.1
|
22
|
Sodium dichloroisocyanate thymol spectrophotometery
|
Urea
|
0.5~5.0ppm
|
0.1ppm
|
≤5%±0.1
|
23
|
Iodine
spectrophotometry
|
Active
chlorite(H)
|
0.05%~15.00%
|
100ppm
|
≤250ppm
|
24
|
Iodine spectrophotometry
|
Active chlorite(L)
|
5~500ppm
|
1ppm
|
≤10ppm
|
25
|
PAN-OP
spectrophotometry
|
Zinc
|
0.05~3.00ppm
|
0.01ppm
|
≤3%±0.01
|
26
|
2,9-Dimethyl-1,10- Phenanthroline spectrophotometry
|
Copper
|
0.2~5.0ppm
|
0.1ppm
|
≤3%±0.1
|
27
|
5-Br-PADAP-OP
spectrophotometry
|
Cadmium
|
0.02~1.00ppm
|
0.01ppm
|
≤3%±0.01
|
28
|
Salicylfluorone spectrophotometry
|
Titanium
|
0.02~0.30ppm
|
0.01ppm
|
≤3%±0.01
|
29
|
Iodine
spectrophotometry
|
Hydrogen
peroxide
|
0.1~50.0ppm
|
0.1ppm
|
≤3%±0.1
|
30
|
Thiocyanate
spectrophotometry
|
Molybdenum
|
0.1~20.0ppm
|
0.1ppm
|
≤3%±0.1
|
31
|
Thiocyanate spectrophotometry
|
Molybdate
|
0.2~35.0ppm
|
0.1ppm
|
≤3%±0.1
|
32
|
Iodine
spectrophotometry
|
Sulfite
|
1~35ppm
|
1ppm
|
≤3%±1
|
33
|
Nephelometry Method
|
Cyanuric acid
|
5-200ppm
|
1ppm
|
≤3%±1
|
34
|
DPD
spectrophotometry
|
Iodine
|
0.10~15.0ppm
|
0.01ppm
|
≤3%±0.01
|
35
|
4-Dimethylamino benzaldehyde
|
Hydrazine
|
0.01~3.00ppm
|
0.001ppm
|
≤3%±0.001
|
36
|
DPD
spectrophotometry
|
Bromine
|
0.1~10.0ppm
|
0.01ppm
|
≤3%±0.01
|
37
|
AHMT
spectrophotometry
|
Formaldehyde
|
0.05~2.00ppm
|
0.01ppm
|
≤3%±0.01
|
38
|
Barium sulfate
turbidimetry
|
Sulfate
|
5~80ppm
|
1ppm
|
≤5%
|
39
|
Turbidimetry
|
Barium
|
2~100ppm
|
1ppm
|
≤3%±1
|
40
|
Xylenol Orange disodium salt spectrophotometry
|
Lead
|
0.5~5.0ppm
|
0.1ppm
|
≤3%±0.1
|
41
|
Sodium tetraphenylborate
spectrophotometry
|
Potassium
|
0.5~10.0ppm
|
0.1ppm
|
≤3%±0.1
|
42
|
Potassium periodate spectrophotometry
|
Manganese
|
0.3~30.0ppm
|
0.1ppm
|
≤3%±0.1
|
43
|
acid-base indicator
spectrophotometry
|
Total alkalinity
|
10~200ppm
|
10ppm
|
≤3%±10
|
44
|
Calmagite spectrophotometry
|
Calcium hardness(H)
|
5~400ppm
|
1ppm
|
≤3%±1
|
45
|
Calmagite
spectrophotometry
|
Magnesium
hardness(H)
|
10~400ppm
|
1ppm
|
≤3%±1
|
46
|
Calmagite spectrophotometry
|
Total hardess
(H)
|
5~400ppm
|
1ppm
|
≤3%±1
|
47
|
Calmagite
spectrophotometry
|
Calcium
hardness(L)
|
0.05~4.00ppm
|
0.01ppm
|
≤3%±0.01
|
48
|
Calmagite spectrophotometry
|
Magnesium hardness(L)
|
0.10~4.00ppm
|
0.01ppm
|
≤3%±0.01
|
49
|
Calmagite
spectrophotometry
|
Total hardess
(L)
|
0.05~4.00ppm
|
0.01ppm
|
≤3%±0.01
|
50
|
Eriochrome cyanine R spectrophotometry
|
Beryllium
|
0.001~0.080pp
m
|
0.001ppm
|
≤3%±0.001
|
51
|
3,5-Br2-PADAP
spectrophotometry
|
Silver
|
0.02~2.00ppm
|
0.01ppm
|
≤3%±0.01
|
52
|
Salicylic acid Method
|
Ammonia nitrogen
|
0.02~2.00ppm
|
0.01ppm
|
≤3%±0.01
|
53
|
standard buffer solution
spectrophotometry
|
PH
|
6.5-8.5
|
0.1
|
≤5%±0.1
|
54
|
Phosphoric spectrophotometry
|
Trivalent chromium
|
20~5000ppm
|
10ppm
|
≤3%±10
|
55
|
PAN
spectrophotometry
|
Cobalt
|
0.02~5.00ppm
|
0.01ppm
|
≤3%±0.01
|
56
|
Phosphorus molybdenum blue spectrophotometry
|
Total phosphorus
|
0.01~20.0ppm
|
0.01ppm
|
≤3%±0.01
|
57
|
Phosphorus molybdenum blue
spectrophotometry
|
Phosphate
|
0.01~4.00ppm
|
0.01ppm
|
≤3%±0.01
|
58
|
Silicon Molybdenum blue spectrophotometric method
|
Silicate
|
0.1~15.0ppm
|
0.1ppm
|
≤3%±0.1
|
59
|
SPADNS
spectrophotometry
|
Fluoride
|
0.1~2.0ppm
|
0.1ppm
|
≤3%±0.1
|
60
|
Potassiumm dichromate spectrophotometry
|
CODcr(L)
|
0~150ppm
|
1ppm
|
≤3%±1
|
61
|
Potassiumm dichromate
spectrophotometry
|
CODcr(H)
|
100~5000ppm
|
10ppm
|
≤3%±10
|
62
|
Turbidimetry
|
Turbidity
|
0.0-200NTU
|
0.1NTU
|
≤3%±1
|
63
|
Platinum-cobalt standard method
|
Chrominance
|
0-500
|
1
|
≤3%±1
|
64
|
Dimethylglyoxime
|
Nickel
|
0.1-20.0ppm
|
0.1ppm
|
≤3%±0.1
|
65
|
2,7-
Naphthalenedisulfonica cid spectrophotometry
|
Boron
|
0.2-2.0
|
0.1ppm
|
≤3%±0.1
|
66
|
4-amino antipyrine spectrophotometery
|
Phenol
|
0.10-5.00ppm
|
0.01ppm
|
≤3%±0.01
|
67
|
Persulfate oxidation spectrophotometery
|
Total Nitrogen
|
0.5~25.0mg/L
、2.0~
100.0mg/L
|
O.1ppm
|
≤3%±0.1
|
bio-equip.cn
As professional designer, manufacturer and OEM producer for laboratory analysis, testing, measuring instruments, which incorporated in January 2006 in Shanghai, China, YK Scientific Instrument Co.,Ltd offers products like UV Visible Spectrophotometer, Analytical Balances, Water testing facilities like Conductivity / PH meter, Moisture Analyzer and etc, for varies industries & fields .
Currently we are producing an exceptional line ofinstruments that are ideal for the following
applications:
-Medical Chemistry
-Environmental Labs
-Biochemistry Labs
-Water/Waste Water Analysis labs
-Agriculture Labs
-Petrochemical Labs
-Food Processing
-Quality Control Labs
-DNA/RNA Testing
-Pharmaceutical Labs
-Chemistry Labs
-Hospital and Research Labs
|