Login    Join free Add to favorites    中文
Home >Products> Physicial & Chemical Analysis >Other Physicial & Chemical Analysis> Kjeldahl Auto Analyzer
Physicial & Chemical Analysis:  PH Meters / Conductance   Other Physicial & Chemical Analysis  
Kjeldahl Auto Analyzer
Kjeldahl Auto Analyzer
Origin of place China
Model JK9870A
Supplier Elite Lab-Equipment Co., Ltd
Price
Hits 655
Updated 5/13/2022
  • Product Detail
  • Company Profile

The working principle of JK9870A auto Kjeldahl analyzer is based on the classical methods, it's namely the "color method" developed auto Kjeldahl analysis system. It is consistent with national and international standards and methods of Kjeldahl nitrogen. JK9870A is a high cost-performance instrument, all of its technical indexes have reached and / or even better than most of oversea similar products. Adoption of lot of patented technologies and components, making its performance overall better than the similar products on present market.

Advantages & Characteristics

Ø Addition of reagents, distillation, titration, analysis and calculation, record (data) storage, waste discharge and titration cup cleaning, all the above-mentioned program can be accomplished by simply click on ONE BUTTON.

Ø Display. 10-inch color touch screen, bilingual operating system (English & Chinese), interactive mode of operation.

Ø Titration curve display. Real-time observation, analysis to the titration process to see whether it's successful or fail and figure out the reason through curve. It's also able to analyze and determine whether the choice of titration is correct through the curve.

Ø High-integrated modular structure. Patented technology of "modular construction" is composed of steam section, titration section, control section, and crate section; therefore, the structure ensures reliable operation and easy maintenance.

Ø Titration cup exposed structure. It's convenient for users to observe and take out cup for cleaning.

Ø The system adopts the CPC company (US) fast for fluid pipe, to ensure that the system not leakage and prolong the life of equipment. The unique color label and color ring system which is able to help user avoid twisting and wrong operation.

Ø Fertilizer (nitro) analysis mode. Addition of fertilizer analysis capability achieves multi-purpose instrument which may save considerable cost for user.

Ø Multi-alkali adding technology. In the operation process, multi-alkali adding technology solves the problem of halfway quit in the analysis process which is due to shortage of alkali adding.

Ø The titrant concentrations autonomous calibration. This patented technology has solved the problem of titrant concentration calibration error by manual calibration, thus the result of analysis is more reliable.

Ø Steam flow adjustment. Steam flow output can be adjusted in accordance with user's needs. This innovation has solved the intractable headache on high concentration sample analysis..

Ø Recipe management system. To provide users with 10 sorts of different analytical formulas which are independent programming can be adopted at any time.

Ø Intelligent cooling system interface. After being connected with the "Intelligent Refrigeration Cycler" which Elite standing behind, "system-wide auto control" can be achieved completely and without having extra water source.

Ø Wireless mouse. Reduce operation intensity.

Safety Protection System

Ø Overtemperature protection system. It's composed of temperature sensor, CPU, overtemperature and overpressure protection system which is able to effectively prevent overtemperature and / or overpressure phenomena due to system failure to ensure a worry-free working condition for user.

Ø Distillation System water shortage alarm function. When the water level is too low or dry, the distillation pot may stop working and alarm systems, which is able to prevent the harm caused by water shortage or dryness effectively.

Ø Absence of protection of the digestive tube. When the digestive tube is not put in place, the system does not run, without alkali, distillation, wounding prevent wounding by reagent and / or contamination.

Specifications

Name of Item

JK9870A

Analysis of the range

0.1-240 mg of N

Repeatability (RSD)

1% or less (30 MGN, 0.1 mol/L H +)

Titration accuracy

 0.75 mu L /Step

Recovery rate

≥99.5%

Sample analysis time (cooling water temperature 18 ℃)

4 to 6 min

Cooling water flow switch

Yes

Cooling water flow rate

Yes

Operating mode

Automatic/manual analysis

Titrant concentration calibration method

Manual input/automatic calibration

Digestive tube liquid automatic discharge

Yes

Distilled from liquid temperature test sample

Yes

Titration curve shows

Yes

Alkali pipeline automatic cleaning

Yes

The temperature sensor

Yes

The cooling water system for intelligent interface\

Yes

The USB interface

Yes

Heating power

2000 w

 Optional Equipments & Accessories

Ø Sample mill

Ø Thermostatic heating digestion system

Ø Extraction apparatus

Ø Neutrodyne system

Ø Digestive tube stand

Ø Digestive tube

Ø Catalytic

Ø Reflux funnel

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号