Login    Join free Add to favorites    中文
Home >Products> Cryostat | Freezers | Thermostat >Water Baths & Circulators> -20~100deg C 30liter Low Temperature Water Bath (DC-2006)
-20~100deg C 30liter Low Temperature Water Bath (DC-2006)
-20~100deg C 30liter Low Temperature Water Bath (DC-2006)
Origin of place China
Model DC-2006
Supplier Golden motor industry group., Co., Limited
Price $686
Hits 987
Updated 8/11/2015
  • Product Detail
  • Company Profile

Product Description


Specifications
 
1.cooling fast; 
2.temperature high precision; 
3.overheating protection 
4.Refrigerating system overcurrent 


 
DC Series Low Temperature Water Bath, Chiller Bath
 Model Temperature(ºC) Temperature uniformity
(Horizontal / vertical ºC)
  Glycol
Sink Dimension(mm)
(L*W*H)
Capacity(L) Sink Front Opening
 (mm2)
Power(W)   Circulating Pump Flow (L/min)   EXW price
   (USD)
DC-0506-II -5~200 ±0.05 275×195×120 6 180×140 600 13 1025
DC-0510-II -5~200 ±0.05 275×195×180 10 180×140 900 13 1084
DC-0515-II -5~200 ±0.05 300×250×200 15 235×160 1500 13 1261
DC-0520-II -5~200 ±0.05 300×250×270 20 235×160 2000 13 1386
DC-0530-II -5~200 ±0.05 440×325×210 30 310×280 2700 13 1704
DC-0550-II -5~200 ±0.05 500×340×300 50 350×300 4000 13 2419
DC-05100-II -5~200 ±0.05 625×400×400 100 400×380 7000 13 3836
DC-1006-II -10~200 ±0.05 275×195×120 6 180×140 800 13 1055
DC-1010-II -10~200 ±0.05 275×195×180 10 180×140 1200 13 1121
DC-1015-II -10~200 ±0.05 300×250×200 15 235×160 1800 13 1254
DC-1020-II -10~200 ±0.05 300×250×270 20 235×160 2300 13 1512
DC-1030-II -10~200 ±0.05 440×325×210 30 310×280 3000 13 1873
DC-1050-II -10~200 ±0.05 500×340×300 50 350×300 4300 13 2766
DC-10100-II -10~200 ±0.05 625×400×400 100 480×380 7500 13 4426
DC-2006-II -20~200 ±0.05 275×195×120 6 180×140 1200 13 1106
DC-2010-II -20~200 ±0.05 275×195×180 10 180×140 1600 13 1224
DC-2015-II -20~200 ±0.05 300×250×200 15 235×160 2200 13 1367
DC-2020-II -20~200 ±0.05 300×250×270 20 235×160 2700 13 1755
DC-2030-II -20~200 ±0.05 440×325×210 30 310×280 3400 13 2124
DC-2050-II -20~200 ±0.05 500×340×300 50 350×300 4700 13 3098
DC-20100-II -20~200 ±0.05 625×400×400 100 480×380 7900 13 4923
DC-3006-II -30~200 ±0.05 275×195×120 6 180×140 1700 13 1239
DC-3010-II -30~200 ±0.05 275×195×180 10 180×140 2100 13 1387
DC-3015-II -30~200 ±0.05 300×250×200 15 235×160 2700 13 1755
DC-3020-II -30~200 ±0.05 300×250×270 20 235×160 3200 13 2028
DC-3030-II -30~200 ±0.05 440×325×210 30 310×280 3900 13 2323
DC-3050-II -30~200 ±0.05 500×340×300 50 350×300 5200 13 3880
DC-30100-II -30~200  ±0.05 625×400×400 100 480×380 8400 13 5606
DC-4006-II -40~200 ±0.05 275×195×120 6 180×140 2300 13 2043
DC-4010-II -40~200 ±0.05 275×195×180 10 180×140 2900 13 2198
DC-4015-II -40~200 ±0.05 300×250×200 15 235×160 3400 13 2420
DC-4020-II -40~200 ±0.05 300×250×270 20 235×160 3900 13 2869 
DC-4030-II -40~200 ±0.05 440×325×210 30 310×280 4600 13 3319
C-4050-II -40~200 ±0.05 500×340×300 50 350×300 5800 13 4773
DC-40100-II -40~200 ±0.05 625×400×400 100 480×380 9000 13 6470
DC-5006-II -50~200 ±0.05 275×195×120 6 180×140 2700 13 3157
DC-5010-II -50~200 ±0.05 275×195×180 10 180×140 3400 13   3364
DC-5015-II -50~200 ±0.05 300×250×200 15 235×160 3900 13   3777
DC-5020-II -50~200 ±0.05 300×250×270 20 235×160 4500 13   4131
DC-5030-II -50~200 ±0.05 440×325×210 30 310×280 5200 13 4773
DC-5050-II -50~200 ±0.05 500×340×300 50 350×300 6400 13 5643
DC-50100-II -50~200 ±0.05 625×400×400 100 480×380 9800 13 7451
 
 
 
 
 
 
 
 
 
Best low temperature thermostatic water bath
 
Application:
Low Temperature  Water Bath is widely used in the fields of biological engineering, medicine, food, chemical industry, chemical analysis, petroleum, etc, providing a constant high precise, controlled, temperature homogeneours place for users. Its temperature is controlled by microprocessor with PID regulator. It has such advantages as fastness in temperature rising and dropping, high precision in controlling temperature.
 
 
Features:
DC series of low-temperature Water bath main performance Description:
 
1. whole sealing refrigeration compressor, refrigeration system is overheating, over-current protection device of multiple
 
2. Circulating pump can be constant temperature liquid tank outside the guidelines, a second constant temperature field.
 
3. Tank of cold liquid can be introduced outside, cooler outside the experimental container, but also in the slot directly to low-temperature, constant temperature experiment
 
4. Using XMT analog and digital PID control system, temperature LCD display.
 
5. Liner, countertops are stainless steel, clean, beautiful and corrosion resistance. 
 
 
Specification:
 
 
 
Key Features:
 
1. Air-cooled closed refrigeration compressor, cooling fast;
 
2. Microcomputer intelligent control, temperature high precision;
 
3. Digital definition reaches 0.1°C or 0.01°C,with function of revise temperature departure;
 
4. Overheating protection, automatic cut power source and alert;
 
5. Refrigerating system overcurrent or overheating automatic protection.
 
 
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号