T Series Cooling Circulating Pump
 
Product Description:
BILON brand T series of cooling device. Use refrigerating compressor, the fluid is cooling down through heat exchange then circulating by a pump. At the same time using temperature controller for temperature control, it has functions of constant temperature, cooling and circulating.
Application:
1. Analysis instrument: atomic absorption, mass spectrometer, polar scope
2. Medical equipment: cooling blanket
3. Industrial equipment and laser equipment: biological pharmacy
4. Scientific experiment equipment: molecular pump rotary evaporation apparatus, distiller, fermentation device, laser, metal rapid prototyping equipment, vacuum coating
Main features:
- Original installation imported compressor, high efficiency.
- Equipped with casters in order to move more convenient.
- Sensitive touch keys make easier operation.
- There is a drain outlet on the bottom. This design can makes fluid exchange become easier.
- It has parameters memory, can self recovery from power off.
- The sink is made of stainless steel, clean, elegant and corrosion resistance.                                             .
- Side inlet and exhaust, adopt round corner design in order to prevent accidental injury.
Round barrel type liner, the fluid cycling more uniform and no blind angle; and no coil-tube inside so as to make full use of space.
Parameters:
Table 1 
Model
 Temperature Range
(°C)
Temperature Control Method
Capacity of Tank
(L)
Max Flow(L/min)
 Cycle Mode
Internal Size(cm)
Max Pump Lift(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-501S
-5°C~RT
On/Off
5
20
External Circulation
20×20
10
600
220V 50HZ
BILON-T-502S
-10°C~RT
600
BILON-T-503S
-20°C~RT
600
BILON-T-504S
-30°C~RT
900
BILON-T-505S
-40°C~RT
900
BILON-T-506S
-60°C~RT
1250
BILON-T-507S
-78°C~RT
1250
BILON-T-508S
-100°C~RT
1250
BILON-T-509S
-120°C~RT
1250
Table 2
Model
 Temperature Range
(°C)
Temperature Control Method
Capacity of Tank
(L)
Max Flow(L/min)
 Cycle Mode
Internal Size
(cm)
Max Pump Lift(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-801S
-5°C~RT
On/Off
8
20
External Circulation
25×18
10
800
220V 50HZ
BILON-T-802S
-10°C~RT
800
BILON-T-803S
-20°C~RT
800
BILON-T-804S
-30°C~RT
1200
BILON-T-805S
-40°C~RT
1200
BILON-T-806S
-60°C~RT
1250
BILON-T-807S
-78°C~RT
1250
BILON-T-808S
-100°C~RT
1250
BILON-T-809S
-120°C~RT
1250
Table 3
Model
 Temperature Range
(°C)
Temperature Control Method
Capacity of Tank
(L)
Max Flow(L/min)
 Cycle Mode
Internal Size(cm)
Max Pump Lift
(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-1001S
-5°C~RT
On/Off
10
20
External Circulation
25×25
10
800
220V 50HZ
BILON-T-1002S
-10°C~RT
800
BILON-T-1003S
-20°C~RT
800
BILON-T-1004S
-30°C~RT
1200
BILON-T-1005S
-40°C~RT
1200
BILON-T-1006S
-60°C~RT
1750
BILON-T-1007S
-78°C~RT
1750
BILON-T-1008S
-100°C~RT
1750
BILON-T-1009S
-120°C~RT
1750
 Table 4
Model
 Temperature Range
(°C)
Temperature Control Method
Capacity of Tank(L)
Max Flow(L/min)
 Cycle Mode
Internal Size(cm)
Max Pump Lift
(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-1601S
-5°C~RT
On/Off
16
20
External Circulation
30×24
 
10
1200
220V 50HZ
BILON-T-1602S
-10°C~RT
1200
BILON-T-1603S
-20°C~RT
1200
BILON-T-1604S
-30°C~RT
1600
BILON-T-1605S
-40°C~RT
1600
BILON-T-1606S
-60°C~RT
1600
BILON-T-1607S
-78°C~RT
2000
BILON-T-1608S
-100°C~RT
2000
BILON-T-1609S
-120°C~RT
2000
 Table 5
Model
 Temperature Range
(°C)
Temperature Control Method
Capacity of Tank
(L)
Max Flow(L/min)
 Cycle Mode
Internal Size(cm)
Max Pump Lift
(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-2001S
-5°C~RT
On/Off
20
20
External Circulation
30×30
10
1200
220V 50HZ
BILON-T-2002S
-10°C~RT
1200
BILON-T-2003S
-20°C~RT
1200
BILON-T-2004S
-30°C~RT
1600
BILON-T-2005S
-40°C~RT
1600
BILON-T-2006S
-60°C~RT
1800
BILON-T-2007S
-78°C~RT
2000
BILON-T-2008S
-100°C~RT
2000
BILON-T-2009S
-120°C~RT
2000
 Table 6
Model
 Temperature Range
(°C)
Temperature Control Method
Capacity of Tank
(L)
Max Flow(L/min)
 Cycle Mode
Internal Size(cm)
Max Pump Lift
(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-3001S
-5°C~Ambient
On/Off
30
40
External Circulation
35×35
14
1800
220V 50HZ
BILON-T-3002S
-10°C~Ambient
1800
BILON-T-3003S
-20°C~Ambient
1800
BILON-T-3004S
-30°C~Ambient
2200
BILON-T-3005S
-40°C~Ambient
2200
BILON-T-3006S
-60°C~Ambient
2500
BILON-T-3007S
-78°C~Ambient
2500
BILON-T-3008S
-100°C~Ambient
2500
BILON-T-3009S
-120°C~Ambient
2500
Table 7
Model
 Temperature Range
 (°C)
Temperature Control Method
Capacity of Tank
(L)
Max Flow(L/min)
 Cycle Mode
Internal Size(cm)
Max Pump Lift
(M)
Cooling Capacity at 20°C(W)
Power
BILON-T-5001S
-5°C~Ambient
On/Off
50
120
External Circulation
40×42
8.6
3500
380V 50HZ
BILON-T-5002S
-10°C~Ambient
3500
BILON-T-5003S
-20°C~Ambient
3500
BILON-T-5004S
-30°C~Ambient
4400
BILON-T-5005S
-40°C~Ambient
4400
BILON-T-5006S
-60°C~Ambient
6000
BILON-T-5007S
-78°C~Ambient
6000
BILON-T-5008S
-100°C~Ambient
6000
BILON-T-5009S
-120°C~Ambient
6000
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号